Part Number Hot Search : 
GC11822F 75000 BTM774 AP201409 02205 IRFB4227 CT2566 M3611
Product Description
Full Text Search
 

To Download MTX-250 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com 250, 350 watts multiple output telecom mtc series model pwr output #1 output #2 output #3 output #4 max-254-1205 250 +5v @ 35a +12v @ 8/12a pk -12v @ 4a -5.2v @ 2a max-353-0512 350 +5v @ 50a +12v @ 8/12a pk -12v @ 4a max-354-1205 350 +5v @ 50a +12v @ 8/12a pk -12v @ 4a -5.2v @ 2a max-354-1212 350 +5v @ 50a +12v @ 8/12a pk -12v @ 4a 12v @ 2a max-354-1224 350 +5v @ 50a +12v @ 8/12a pk -12v @ 4a +24v @ 1.5a standard max series model pwr output #1 output #2 output #3 output #4 mtx-253-0512 250 +5v @ 35a +12v @ 8/12a pk -12v @ 2a mtx-254-1205 250 +5v @ 35a +12v @ 8/12a pk -12v @ 2a +5v @ 1.5a mtx-254-1212 250 +5v @ 35a +12v @ 8/12a pk -12v @ 2a +12v @ 2a small computer mtx series model pwr output #1 output #2 output #3 msc-353-0512 350 +5v @ 30a +12v @ 20/2 a pk -12v @ 4a mass storage msc series max-250 max-350 mtc-250 mtc-350 MTX-250 msc-350 featuring: over 3 watt/in 3 power density 80% overall efficiency meets international safety agency requirements all outputs regulated 1% high peak currents for motor starting system air or self-cooling options ac automatic line selection option available in 24, 28, or 48 vdc input the appropriate mtc, max, or mtx in your telecom product gives you the out- puts you need for isdn, lan, and t1 applications and standard voice and data networks. high-current auxiliary outputs provide regulation characteristics for prop- er operation of line drivers, network inter- faces and rs232-type outputs. or, use a 9-inch msc in your computer-based product for needed output regulation, power for 50 amps of logic and four hard disk drives. and, you can increase power by 40% as you add peripherals ?without redesigning for a larger power supply by upgrading from the mdt 160/220 series. check the specifications of these low- profile, 9-inch switchers that give you more design freedom. model pwr output #1 output #2 output #3 mtc-253-0515 250 +5v @ 30a +15v @ 4a -15v @ 4a mtc-353-0512 350 +5v @ 45a +12v @ 6a -12v @ 6a mtc-353-0515 350 +5v @ 45a +15v @ 5a -15v @ 5a option c option v
condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com 250, 350 watts 9x 5x 2.5 max, msc, mtc, mtx function 115 vac 230 vac connector input select short open 0.187 male fastons tb1- line line 1 tb1- neutral line 2 tb1- safety ground safety ground ac input function max, mtc, mtx msc connector output #1 terminal marked +v terminal marked com output #2 tb2-3 (+) tb2-2 (+) tb2-4 rtn (common) tb2-1 rtn (common) output #3 tb2-5 (? tb2-3(? tb2-4 rtn (common) tb2-1 rtn (common) output #4* tb2-1 (+) (if provided) tb2-2 (? *rtn connected to common only if output is polarized in product selection chart dc output barrier strip #6-32 screws 3/8?centers bus bars #10/32 screws barrier strip #6-32 screws 3/8?centers function location notes connector j1-1(+ s) output #1 sense j1-2 (?s) output #1 sense rtn ac power fail or j1-3 (pf) reference to j1-2 dc power good* inhibit j1-4 (ih) short to j1-2 *optional function status and control amp mta type #640456-4 pin header (locking) remote sense specifications: all models input ac input: 90-132 vac/180-264 vac, 47 to 63 hz. user selectable. see option ??for automatic line selection. internally fused for 10 a. inrush: cold start ac current is less than 10 a at 115 vac and 18 a at 230 vac. for mtx models, 10 a at 115 vac and 20 a at 230 vac. limited by thermistor. holdup time: 16 ms minimum after removal of power, at nominal line, full load. efficiency: 80% typical. brownout protection: holds regulation to 85 vac or 170 vac. output adjustability: user adjustable ?% minimum. line & load reg: ?% over ac input range and 0 to 100% load change. output #1 requires minimum load of 10%. ripple & noise: less than 1% p-p or 100 mv, whichever is greater. remote sense (output #1) : compensates for 250 mv total line drop. open sense lead protection. temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response (output #1) : output voltage returns to within 1% in less than 500 ? for a 50% load change. peak transient does not exceed 5%. overload protection: all outputs are protected against overload and short circuit. automatic recovery upon removal of fault. overvoltage protection (output #1) : protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. remote inhibit: contact closure to the negative sense line drops output power to nominal zero. reverse voltage: protected against reverse voltage up to supply current rating. environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 50? at full ratings. derate to half power at 70?. safety agencies: most models are approved to ul1950; csa 22.2 #234; iec 950 and t?v en60950, class 1 selv., ce 72/23/eec/93/68eec (low voltage directive). conducted rfi: meets fcc part 15, subpart j, class a; en55022 class b; cispr 22 class b. cooling: 30 cfm required to achieve full ratings. output isolation: isolated from ground 50 vdc. options: option ?? ac auto-range: automatically selects proper ac line voltage range to enable power operation at either 115 or 230 vac without user intervention. option ?? cover: limits contact with power supply interior. option ?? fan/cover assembly: cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50? ambient temperature. option ?? dc power good: provides a ttl ??open collector when output #1 is above 4.6 v nominal. not available if option ??is selected. max, msc, mtc, mtx with option f 3.9 lbs - 1.8 kgs max, msc, mtc, mtx 3.4 lbs - 1.5 kgs option ?? ac power fail: provides ttl ?? 5 ms before output voltage goes out of regulation band upon loss of ac power. vmebus compatible, provides 48 ma sink current capability. not available if option ??is selected. option ?? fan/cover assembly: low profile, end venting cover with integral ball-bearing fan. consult factory for other available options. *9.05 229.87 for mtx dimensions: inches millimeters (l) (n) ( )


▲Up To Search▲   

 
Price & Availability of MTX-250

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X